Fire Extinguisher Service in Duncanville, TX

Sales, inspection, maintenance, recharging and replacement, with the placement across the building checked as carefully as the cylinders themselves, under Texas Certificate of Registration ECR-1366.

A cylinder is only compliant where the code says it has to hang

An extinguisher program covers more than the can on the wall. We sell the correct class of extinguisher for the hazard it is protecting, inspect the full inventory on a set schedule, maintain and recharge units that have been discharged or have aged out of their service interval, and replace anything that fails. Placement across a facility is checked against travel distance and hazard class at the same time, because a fully charged extinguisher in the wrong spot fails an inspection just as surely as an empty one.

Monthly walkthrough, annual service

Two different checks apply to the same extinguisher. A monthly visual walkthrough confirms the unit is in place, the gauge reads charged, the pin and seal are intact and the access is not blocked. An annual maintenance inspection goes further, a full internal check performed by a licensed technician who tags the unit with the date of service. Both matter, and a building that only does one of them is not actually covered.

Texas Fire Extinguisher Certificate of Registration ECR-1366. Call (972) 298-2772.

Freshly installed red Chemguard foam bladder tank on poured concrete pads with red trim piping and a sight glass

FEL-B-1989548 · FEL-K-2455585 · technician licences

The person who tags your extinguisher is licensed to.

Texas licenses fire extinguisher technicians by class of work. Our roster carries FEL-B licences for the general service, recharge and hydrostatic-test side of the work, and FEL-K licences for kitchen suppression and Class K units, which behave differently under heat than an ordinary dry-chemical extinguisher. Cole Parker holds the FEL-K registration on staff.

Both licence classes are held alongside the Texas Fire Extinguisher Certificate of Registration ECR-1366 the company operates under, and every number can be checked on our licences page.

Est. 1995 · 1147 S. Cedar Ridge Dr., Duncanville

Placement, travel distance, and the right class for the hazard.

An extinguisher has to be reachable within a set travel distance of the hazard it covers, and the class rating printed on the label has to match what is actually in the room, an ordinary combustible, a flammable liquid, an energized electrical panel or a commercial kitchen. Getting the class wrong is a worse outcome than getting the count wrong, because the wrong agent on the wrong fire can make it worse.

We run this program alongside the rest of a building's fire protection systems, which is what makes the annual inspection a single visit instead of three.

Call (972) 298-2772 to get an extinguisher program started, or read where else we work on the projects page.

Automatic Sprinkler of Texas building at 1147 South Cedar Ridge Drive, Duncanville, with the company sign reading Est. 1995